»  Specifications
»  Motor Performance
»  Dimensions
»  QuickStart Kit
»  Part Numbering and     Connectivity
»  Options
»  Encoders
»  Literature
»  Software
»  Additional Resources

»  Contact IMS

 

The MDrive34Plus Microstepping is a NEMA 34 size high torque stepping motor integrated with an advanced, high resolution microstepping driver. Features include:

  • Advanced current control for unsurpassed smoothness and performance
  • 20 microstep resolutions from full step to 51,200 steps per revolution
  • Optically isolated logic can accept sinking or sourcing inputs ranging from +5 to +24 VDC
  • All parameters are software configurable (setup utility included) - no external switches or resistors require
MDrive34Plus
Base Version

MDrive34Plus
Pluggable Interface

Specifications
Open Print View

  • General
  • Motion
  • Communication
  • Setup Parameters
  • Motor
Input Voltage Range (includes back-EMF) +12 to +75 VDC
Power Supply Current Requirement Max per MDrivePlus (Depends on voltage and load) 4.0 A
Isolated Inputs (Step Clock, Direction and Enable) Sinking or Sourcing voltage +5 to +24 VDC
Current (+5 VDC Max) 8.7 mA
Current (+24 VDC Max) 14.6 mA
Operating Temperature Measured at Heat Sink (non-condensing humidity) -40° to 75°C
Measured at Motor (non-condensing humidity -40° to 90°C
Digital Filter Range   50 nS to 12.9 μS (10 MHz to 38.8 kHz)
Clock Types   Step/Direction, Step Up/Step Down, Quadrature
Step Frequency   2 MHz (Default) 5 MHz (Max)
Microstep Resolution Number of Settings 20
Steps per Revolution 200, 400, 800, 1000, 1600, 2000, 3200, 5000, 6400, 10000, 12800, 20000, 25000, 25600, 40000, 50000, 51200, 36000 (0.01 deg/μstep), 21600 (1 arc minute/μstep), 25400 (0.001mm/μstep)
Protocol SPI (Serial Peripheral Interface)
Isolation Galvanic
  Function Range Units Default
MHC Motor Hold Current 0 to 100 Percent (%) 5
MRC Motor Run Current 1 to 100 Percent (%) 25
MSEL Microstep Resolution See Spec Motion Settings Tab µsteps/step 256
DIR Motor Direction Override CW/CCW CW
HCDT Hold Current Delay Time 0 or 2 to 65535 msec 500
CLK TYPE Input Clock Type Step/Dir, Up/Down, Quadrature Step/Dir
CLK IOF Clock and Direction Filter 50 nS to 12.9 μS
(10 MHz to 38.8 kHz)
ns (MHz) 200 (2.5)
USER ID User ID 1 to 3 characters Viewable ASCII IMS
EN ACT Enable Active High/Low High
WARN_TEMP Over Temperature Warning 0 to 125 °C 80
  Single Length Double Length Triple Length
Holding Torque oz-in (N-cm) 381 (269) 575 (406) 1061 (749)
Detent Torque oz-in (N-cm) 10.9 (7.7) 14.16 (10.0) 19.83 (14.0)
Rotor Inertia
oz-in-sec2 (kg-cm2)
0.01416 (1.0) 0.02266 (1.6) 0.04815 (3.4)
Weight Motor+Driver lb (gm) 4.1 (1.9) 5.5 (2.5) 8.8 (4.0)

Motor Performance Curves
Open Print View

Single Length Motor
Double Length Motor
Triple Length Motor

Dimensions
Open Print View

 
 
Base
 
QuickStart Kit
quickstart thumbnail

All-inclusive QuickStart Kits facilitate rapid design verification by bundling any one of over 156,000 MDrivePlus products -- built to your specifications -- with everything needed to connect quickly and conveniently, enabling engineers to confirm with confidence that their application’s design goals are met. QuickStart Kits include: a single sheet instruction guide, software/manuals CD, and connecting cabling including Communications Converter and Prototype Development Cable(s).

Order QuickStart Kits simply by placing a “K-” at the beginning of an MDrivePlus part number

Above photo represents a QuickStart Kit. Kit cabling varies with MDrivePlus ordered.

TO VIEW complete QuickStart Kit components list by MDrivePlus Part #: Interactive MDrivePlus Part Builder.

CONNECTIVITY NOTE: Communications Converters and Prototype Development Cables, in addition to Mating Connector Kits for use in building your own cables, are available separately. Refer to the following section for more complete details.

Part Numbering and Connectivity
Open Print View

mdm23 web order table

P/N:   MDM1FSD34*7
P/N:   MDM1CS 34*7
Interface Connecting OptionsUse the drop-down menu and/or link above to view mating connector interface options by MDrivePlus part number (p/n) defined via the preceding order table or interactive MDrivePlus Part Builder. Note: asterisks (*) are used in part numbers where there is no impact to connector options.

Image left: example of mating connector interface details accessed through pull-down menus above.
 
  • Comm Converters
  • Prototype Development Cables
  • Mating Connector Kits

Electrically Isolated, in-line converters pre-wired with mating connectors to conveniently set parameters and program a single MDrivePlus via a PC USB port.

To view connectivity options for each model MDrive, select from the drop-down listing above.

Converter Part Number Mating Connector Type
MD-CC300-001 (USB to SPI) 10-Pin IDC
MD-CC303-001 (USB to SPI) 12-Pin Tyco

 

If building your own cabling, you will need:

  • SPI inline converter or PC parallel port
  • Cabling with appropriate mating connectors for the MDrive model selected

Prototype development cables are designed to speed test/development with pre-wired mating connectors that have flying leads other end. No prototype development cables are available for the MDrivePlus using the 12' Flying Leads or Pluggable Clamp Terminal Strip.

To view connectivity options for each model MDrive, select from the drop-down listing above.

Prototype Development Cable P/N Mating Connector Type Signal Type
PD12-1434-FL3 12-Pin Locking Wire Crimp I/O and Communications

These Prototype Development Cables will ONLY be used if you are using your own SPI communications converter.

 

If building your own cabling, you will need:

  • Appropriate mating connector and crimp pins if required (Mating connector kits are available for Locking Wire Crimp style connectors)
  • Crimp tooling (Locking Wire Crimp)
  • Shielded twisted pair cabling

Used to build your own cables. Kits contain 5 mating connector shells with pins. Cable not supplied. Manufacturer crimp tooling recommended.

To view connectivity options for each model MDrive, select from the drop-down listing above.

Mating Connector Kit P/N Mating Connector Type Shell Mfg. P/N Crimp Pins Mfg. P/N
CK-03 12-Pin Locking Wire Crimp Tyco:  1-794617-2 Tyco:  794610-1
CK-05 2-Pin Locking Wire Crimp Molex:  510-67-0200 Molex:  502-17-9101
CK-01 10-Pin IDC Samtec:  TCSD-0501-N --

Options

Linear Slide
gearbox
Linear Actuator

Encoders

  • Internal Magnetic Encoder
  • External Optical Encoder

The internal encoder option is a differential magnetic encoder: The internal magnetic encoder offers several key advantages:

  1. Smaller footprint to the MDrive than an externally mounted encoder.
  2. Available line counts: 100, 200, 250, 256, 400, 500, 512, 800, 1000.
  3. Encoder in a closed environment, limited susceptibilty to dust contamination.
  4. Robust output sink current of 20 mA.
  5. May be connected as single-end or differential.

Gives the user the option of using an optical encoder. Available in single-end and differential configurations with the following line counts: 100, 200, 250, 256, 400, 500, 512, 1000, 1024.

Optional encoder cables are available. Order separately.
Single-end Cable (12.0"/30.5cm) ...................ES-CABLE-2 [wire colors]
Differential Locking Cable (6.0'/1.8m) .........ED-CABLE-6 [wire colors]

Literature [Acrobat PDF]

 
datasheet

Software

Additional Resources

 

 

IMS Logo Wide

370 N. Main St., P.O. Box 457
Marlborough, CT 06447 U.S.A.
Phone: 860 / 295-6102
Fax: 860 / 295-6107
Email: info@imshome.com

Contact

TECHNICAL SUPPORT (U.S.A.)
Phone: 860 / 295-6102
Fax: 860 / 295-6107
E-mail: etech@imshome.com

IMS ASIA PACIFIC OFFICE
30 Raffles Pl., 23-00 Chevron House
Singapore 048622
Phone: +65 / 6233 / 6846
Fax: +65 / 6233 / 5044
E-mail: wllee@imshome.com

IMS EUROPEAN SALES MGT.
4 Quai Des Etroits
69005 Lyon, France
Phone: +33 / 4 7256 5113
Fax: +33 / 4 7838 1537
E-mail: bmartinez@imshome.com

IMS UK Ltd
.
Sanderson Centre
15 Lees Lane
Gosport,Hampshire, UK  PO12 3UL
Phone: +44 / 0 2392 520775
Fax: +44 / 0 2392 502559
E-mail: mcheckley@imshome.com

U.S.A. SALES OFFICES
Eastern Region 

Phone: 973 / 661-1270
Fax: 973 / 661-1275
E-mail: jroake@imshome.com

Central Region
Phone: 260 / 402-6016
Fax: 419 / 858-0375
E-mail: dwaksman@imshome.com

Western Region
Phone: 602 / 578-7201
E-mail: dweisenberger@imshome.com