Transitioning to MDrivePlus Motion Control
from
Legacy MDrive
The MDrivePlus Motion Control products represent significant improvements over the legacy MDrives. Based on new patented technology, they feature a richer software command set, improved current control, and enhanced thermal dissipation. Along with these improvements, there may be situations where the MDrivePlus are not "drop-in replacements" for existing legacy MDrives. Some customers may have software that will not run on MDrivePlus units without syntax modifications. There may be timing differences in some command executions that could affect system response. Additionally, it is recommended that customers with close tolerance or clearance situations study the mechanical drawings for the MDrivePlus units. The following summarizes differences and steps required to successfully transition an application that uses a legacy MDrive to an MDrivePlus. Software / Programming Issues HT Command (Hold Current Delay Time) HT=0 in plus units will cause the units to never transition to hold current and the unit will be at the run current percent at all times. HT =1 is the smallest delay time allowable on plus units. Legacy progams with HT=0 should be modified to HT=1 for the same performance and to avoid issues with motor over-heating. Commands and Variables: Here is an alphabetical listing of MDrivePlus commands that should be not be used as a label or variable: |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
New Command to MDrivePlus Reserved Word, not accessible |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Examples: MR 51200 C1=20000 Ver. 3.004 and later:
The latest firmware version is always available for upgrade from this web site (see Support / Product Firmware).
Some MDrivePlus commands vary in execution time from legacy MDrive. Approximate timing for MDrivePlus command execution:
The following times for MDrivePlus are from command entry until the motor begins to move:
Electrical Issues Auxiliary power source through the communication cable MD-CC400-000 is discontinued via IMS Product Advisory dated November 17, 2006. It is recommended that users with existing cable assemblies cover the jack access hole to prevent use. Do not use Communication Ground on Communications Port (P2) for the Auxiliary Power Supply. The open state of a sinking I/O point for MDrivePlus is now 2.3vdc where legacy MDrive was 5vdc. For example: With S1=0,0,0, the open circuit voltage on I/O 1 will read 2.3vdc. RS-485 Connector Changes (P2):
Mechanical Issues MDrivePlus products have some dimensional differences from legacy MDrive in regard to housing geometry and overall depth. If the end user’s fit and clearance is in question, careful review of the published mechanical drawings will be required.
|
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||