Command syntax changes:
Command syntax changes may be an issue prior to firmware version 3.004. Units shipped after December 1, 2006 have version 3.004. MDrivePlus products with earlier firmware require a space between the command and value with motion commands, while variable assignments needed an equal sign.
Examples:
Pre ver. 3.004:
MR 51200
C1=20000
Ver. 3.004 and later:
MR 51200 or MR=51200
C1=20000 C1 20000
The latest firmware version is always available for upgrade from this web site (see Support / Download Software / Product Firmware).
Some MDrivePlus commands vary in execution time from legacy MDrive. Approximate timing for MDrivePlus command execution:
| PG addr |
282 mSec |
| PR Mv |
1.4 mSec |
| PR er |
1.5 mSec |
| S |
600 mSec |
The following times for MDrivePlus are from command entry until the motor begins to move:
| MR dist |
3.5 mSec |
| MA pos |
3.5 mSec |
| SL vel |
0.7 mSec |
| HI type |
0.7 mSec |
| HM type |
0.7 mSec |
Electrical Issues
Auxiliary power source through the communication cable MD-CC400-000 is discontinued via IMS Product Advisory dated November 17, 2006. It is recommended that users with existing cable assemblies cover the jack access hole to prevent use. Do not use Communication Ground on Communications Port (P2) for the Auxiliary Power Supply.
The open state of a sinking I/O point for MDrivePlus is now 2.3vdc where legacy MDrive was 5vdc. For example: With S1=0,0,0, the open circuit voltage on I/O 1 will read 2.3vdc.
RS-485 Connector Changes (P2):
10 Pin IDC (RD option)
| Signal |
Legacy MDrive |
MDrive Plus |
| TX+ |
9 |
9,1 |
| TX– |
8 |
8,2 |
| RX+ |
6 |
6,3 |
| RX– |
7 |
7,4 |
| Gnd |
10 |
10 - Comm Gnd -
100 Ohms to Motor Gnd |
| |
(1–5 no connection) |
5 - Aux Power In |
Mechanical Issues
MDrivePlus products have some dimensional differences from legacy MDrive in regard to housing geometry and overall depth. If the end user’s fit and clearance is in question, careful review of the published mechanical drawings will be required.