'***** Electronic Gearing ***** PG 1 LB k4 PR "Electonic Gearing" Rc=50 'set run current to 50% S7=33,0 'Sets clock type to step input S8=33,0 'Sets clock type to direction input Fm=3 'set filter motion to 1.67 Mhz cutoff freq. Ms=16 'Set microstep resolution to 16 Cm=1 'Clock mode enable Cr=1.0 'Set clock mode ratio to 1:1 E PG